Vikrant Transformers

Navsari 396436- India

Presentation - Vikrant Transformers

Manufacturer & Suppliers of Oil Filled Distribution Transformers, Oil Filled Power Transformers, Furnace Transformer, Induction Transformer. Vikrant Transformers is a reputed manufacturer of power and distribution transformers. We are having fully equipped workshop and technically qualified personnel with rich experience in the field of manufacturing power and distribution transformers upto 2 MVA, 33 KV.Vikrant Transformers was founded in 1991 by an able enterpreneur Mr. Girish Patel. The company is a family owned business that is able to move quickly for its customers, because of its quality practices and philosophy. Our business is helping your business react to market changes quickly and assured through quality and on-time delivery. Our Expertise..
  • Power and distribution transformers up to 2 MVA, 33 KV.
  • For the repairing of weir and distribution transformers upto 5000 KVA, 66 KV.
  • For Transformers oil filtration on site.
  • For installation and commissioning of power and distribution transformers at your site.
  • Annual Contract for servicing of your transformers at your site.
A brief History and bright present... Vikrant Transformers was established in 1991, in Maroli, a town 200 Kms. north of Mumbai. The town is well connected by Rail and Road.  Vikrant Transformers is just 25 kms away from Surat Railway Station, and is 8 Kms away from National Highway No. 8 towards Mumbai.The factory is spreaded over 1.5 acres of land and has a built up area of more than 11,000 square feet comprising of main office block and Transformers Shed.  Vikrant Transformers manufactures oil filled Distribution and Power Transformers, Generator Duty Transformers and Induction Furnace duty Transformers.The company is having one associated company, namely  Sheetal Electricals, located at Maroli. The company provides sales after service, sight overhauling, filtration and repair of all kinds of Transformers.Today,  Vikrant Transformers is well known for its quality of product and has more than 1000 installations all over India with the cooperation of our associated company. Our Transformers are well accepted in the market. Regular orders are received from electricity Boards, Power Projects, Paper, Cement, Steel, Pharmaceuticals, Textile and various other areas. The company is approved by many reputed consultants in this field and successfully supplied transformers through most of them. In India, company has executed large orders for ESSAR, L&T, MSEB, GEB, Colour Tex, Himson and others. Vikrant Transformers manufactures an extensive line of  transformers and transformer styles. We design and manufacture a  product that perfectly suits your specific  application. This makes our product line as varied  as the industries we serve. The products and  industries list that follow demonstrate our  capabilities. 
  • Distribution transformers upto 2000 KVA, 33 KV Class
  • Step up transformers upto 2000 KVA, 33 KV Class
  • Earthing Transformers
  • Low voltage transformers for industrial applications
  • Special transformers to meet customers' specific requirements.
  • Furnace duty transformers.
Transformers are designed and tested as per ISS 2026-1977. The transformers are designed by highly technical and experienced design engineer.We can undertake design manufacture and supply of copper wound transformers upto 2000 KVA capacity and voltage class upto 33 KV. Certain Highlights regarding our Transformers... Core: The core is built up from interleaved cold rolled grain oriented steel laminations, coated with an insulating material which is both heat and oil resistant. The cores are assembled on steel channels and clamped in a manner to reduce vibration and inherent voice to minimum. All cores have mitered joints. Windings: Transformers windings are designed to met three fundamental requirements.  Mechanical, thermal and electrical. They are cylindrical in shape and are assembled concentrically. Interlayer cooling ducts are provided to ensure that the temperature gradient between winding and oil and hence the hot spot temperature is kept as low as possible. This means that the rate of insulation deterioration is minimized and a high life expectancy is achieved. Insulation between layers and turns is based upon the impulse test level of the voltage class of the winding as specified in ISS 2026-1977. Tapping: Tappings are provided on HV voltage +-2.5% and +- 5%. Tap selection is effected by means of an off circuit tapping switch operated by an external handle on the cover. Tank: The tank is made from mild steel which is electrically welded. Tank is adequately stiffened to withstand air pressure of 0.8 Kg/cm2 and vacuum of 0.7 kg/cm2. All tanks are applied with one coat of Zinc Chrome primer and two coats of synthetic enamel paints. The inside of tank is provided with heat and oil resistance paints. Termination: All the bushing and its metal parts are of high quality and confirming to the relevant ISS 3347. Overloads: Transformers can be overloaded in accordance with ISS 6600. Vector Group: The transformers are generally connected DY11 (Delta Star). However we can manufacture on any vector group as per ISS 2026-1977. Operating Conditions: The standard range of transformers described in this specification are designed for continuous operation at rated voltage and frequency resulting top oil temperature rise of 500C by thermometer and 550c of winding of resistance.  Insulation in impregnation: The principal components of insulation are made from high quality pressure board / haldullingum / permawood. The oil used for impregnation confirms to IS 335.  Ability to withstand short circuit: In order to prevent deformation when subjected to short circuit forces, solid block end insulation backed up by substantial supporting frames is utilized. The axial end trust under fault conditions is minimized by the suitable distribution of the ampere turns over the length of the windings and by ensuring that the design dimensions are closely adhered to during manufacturing. The transformers designed and manufactured to withstand short circuit conditions as laid down in ISS 2026-1977.  Tolerance: No load losses, voltage ration, impedance voltage are subject to tolerance as per ISS 2026-1977.  Fittings: Following standard fittings are provided on transformer 
  • Oil conservator with plain oil gauge, filling hole with cap and drain plug.
  • One Silica Gel dehydrating Breather
  • One Off circuit externally operated tapping switch with position indicator, handle and locking device.
  • 4 Bi Directional flat rollers.
  • Explosion Vent
  • 1 Thermometer Pocket.
  • 1 Drain Valve with plug.
  • 2 lifting lugs.
  • 2 earthing terminals.
  • 1 rating and diagram plate
  • 1 Air release plug
  • LT Cable Box
  Optional Fittings Following fittings can be supplied with transformers on customer's request. 
  • HT Cable Box
  • 4" Dial Thermometer with MRP / BSD
  • 6" Dial Thermometer with MRP / RSD and set of alarm contacts ( 230 V, 60 m.A.)
  • Double Float Buchholz Relay with alarm and trip contact.

General Information -  Vikrant Transformers

Certifications

Type: ISO 9001

Location -  Vikrant Transformers

Maroli Village Road, - Maroli, - Navsari 396436 - India

Follow us - Vikrant Transformers

Discover more on our Website Website available

Kompass membership

Kompass ID? IN778293

Legal information - Vikrant Transformers

Other Companies recommended by Kompass:

Looking for new B2B Leads ?

Purchase a Company list with the executives and contact details

  • Verified decision-maker contacts
  • Accurate B2B targeting by sector
  • Immediate Excel/CSV export